Once all the fiber cables are installed and terminated, there is a requirement for Optical Fiber Testing for checking the transmission through them. For every system of fiber optic cable, its transmission continuity and end-to-end loss has to be inspected. We have all the instruments and device in our range for testing optical transmission systems, fiber attenuation and continuous optical signals. All are highly accurate in their measurements with automatic turn- off time that can be set by the operator. There are integrated audio alarms for low battery in order to ensure safety of the cables and device.

SAT 8C Cable Fault Locator

SAT-8C Cable Fault Locator adopts international advanced electronic measurement technology, which is a comprehensive instrument that integrates with ATDR, resistance meter, megohmmeter and automatic bridge. It is applicable for localization of break, cross, poor electric insulation and other faults of various telephone cables, high-frequency cables and coaxial cables. It is a capable for the line maintenance and construction in telecom industry.



FEATURES:-
  • Pulse reflection and intelligent bridge testing method with full-automatic and manual testing functions.
  • Testing for insulation resistance and loop resistance. Insulation reach up to 50 MΩ.
  • Automatically judge the line state: break, cross, poor electric insulation and the high voltage.
  • DAGC (Digital Automatic Gain Control) and DWAR (Digital Waveform Automatic
  • Recognize), it can automatically judge the wave form.
  • Field calibration function (correct speed and line diameter parameter of unknown cable, correct length of known cable, automatic store the correction factor).
  • Default 0.32mm, 0.4mm, 0.5mm, 0.6mm's telephone cables.
  • Store 10 testing waveforms, and upload results to PC, reviewing analyzing and printing.
  • Two waveforms comparison function
  • With USB interface.
  • Built-in lithium battery, and its working 6 hours.



Technical Specifications

Pulse reflection
  • Full-automatic measurement range 0~8 km
  • Testing accuracy: 1 m for measurement range < 2 km; Accuracy ±2% 8 m for measurement range > 2 km; Accuracy ±2%
  • Testing dead zone: 0 m
  • Pulse width: 60ns-10µs automatic adjustment
  • VOP: 0 ~ 300 m /µs
  • Vertical gain: Range: 80 dB; Accuracy: 1 dB
  • Impedance: 135Ω ( accuracy 1% )


Bridge testing method
  • Poor insulation resistance: 0~50MΩ
  • Testing length: Full length 9999m Sectional 9999mx3 sections
  • Testing error: 1% x Full length of line
  • With megohmmeter and ohmmeter's functions


DMM Technical index
  • Insulation resistance: 0 ~ 50MΩ Minimum resolution: 10kΩ, accuracy: ±3%
  • Loop resistance: 0 ~ 9kΩ. Minimum resolution: 0.1Ω, accuracy: ±3%
  • Voltage: AC/DC voltage 0 ~ 250V. Minimum resolution: 0.1V, accuracy: ±5%
  • Capacitance: 0-1.3µF. Minimum resolution: 1nF, accuracy:±5%


Power supply:
  • AC Power: External AC power supply / Charger
  • Battery: Built-in 2Ah lithium-ion rechargeable battery
  • Working time:6 hours
  • Charging time:4 hours


Physical parameters
  • Dimensions(L x W x H): 220 x 162 x 48mm
  • Weight: 0.95kg
  • Screen: 640 x 480 pixels and TFT touch color screen
  • With USB and RJ11 interface
  • Input Protection:± 400 V pk


Ambient parameters
  • Working temperature:-10~ 50 °C
  • Storage temperature:-30~ 70 °C
  • Humidity:5%-90%(non-condensing)


Yes! I am interested




SAT-18C Palm OTDR

SAT-18C Palm OTDR is a handheld and light device, widely used in optical communication testing work. Integrated with an advanced anti-reflective TFT LCD that can be clearly seen, the testing device has options for manual test, auto test and real time test. It can also generate speed curve analysis with multiple curves comparison. For transferring of data to other systems, there is a USB and SD card interface. Built- in lithium battery in the device can work up to 10 hours with special indication for battery status. When it comes to testing, the device has the capability of testing a dynamic range from 26dB to 35dB at 1310/1550nm.

Model SAT-18C1 SAT-18C2 SAT-18C3
Central wavelength(nm) 1310/1550
Type of optical fiber SM
Dynamic range(SNR=1) 26/24dB 30/28dB 35/34dB
Distance measurement accuracy 1m+sample space +0.003%×measurement distance
Event dead zone(m) 1.6/1.6
Attenuation dead zone(m) 4.5/5
Distance range(km) 0.8,1.6,3.2,6.4,12.8,25.6,51.2,102.4,204.8,409.6
Pulse width(ns) 8,16,40,80,160,320,640,1280,2560,5120,10240,20480
Loss threshold(dB) 0.01
Sampling points 128000
Linearity(dB) ±0.03
Wave pattern memory space >1000
Group refractive index setting 1.00000~2.00000
Display 320×240, 3.5 inch TFT color LCD touch screen
Interface USB, SD card
Optical connector FC/PC(ST,SC standard)
VFL and interface power: 2mw; distance: 5Km; FC/PC(universal interface)
Power supply AC/DC adapter: Input: AC 100V~240V, 50/60Hz Output: DC 12V/6A Battery: rechargeable lithium cell 7.4V, 4400mAh, battery working time: 10 hours(normal temperature)
Ambient environment Working temperature: -10?~50?(battery charging: 5?~40?) Storage temperature: -40?~70?(not include battery) Humidity: 5%~95%, non-condensing
Dimension 201mm×100mm×60mm
Weight 1kg

Yes! I am interested

SAT-3E

SAT-3E optical laser source is the most demanded device in telecom sector for testing the optical transmission system and fiber attenuation. Ensures highly accurate measurements, the device has excellent sensitivity towards transmissions. For low battery indication, there is an alarm for warning. The testing laser is integrated with a LCD display and new-type conductive rubber switch that is best suited for different operation environments. There are options of multi wavelengths with up to four wavelengths on two ports. One can easily set the automatic power-off time in the range of 30 to 90 mins for safe performance.

Parameter Technical Parameters
Model 3E11 3E12 3E13 3E14 3E15 3E16 3E17 3E18 3E19
Working Wavelength (nm) 1310 1550 1310
/1550
650
/1310
/1550
850
/1310
/1550
850
/1300
1490
/1310
/1550
1625
/1310
/1550
850
/1300
/1310
/1550
Output power (dBm) 1310/1550:0, -3, -6; 650: >0; 850/1300/1490/1625: -6(error:±0.2) -6(error:±0.2)
Spectrum width = 5 nm
Output stability ±0.03dB/15min; ±0.05dB/8h
Output mode 1310/1550: CW, 270Hz, 1KHz, 2KHz; 650/850/1300/1490/1625: CW
Optical identifying distance 5km; 10km/15km optional (650nm)
Display LCD
Auto turn-off time 30~99mins or none
Interface FC,SC,ST
Power supply 2X1.2V AA nickel-hydrogen rechargeable batteries
Luminous parts LD
Operating temperature -10~+50°C
Storage temperature -40~+70°C
Dimension L X W X H: 140 X 72 X 38 mm
Weight 0.3 kg

Yes! I am interested

SAT-4E

SAT-4E optical power meter has its usage in telecom sector for testing continuous optical signals. It has the function for identifying and measuring multi wavelength with auto frequency of 270HZ, 1 kHz and 2 kHz. It is integrated with RS232 interface from which the data can be loaded to PC for further analysis and evaluation. In this power meter device, the automatic turn- off time can be easily set and the facility of reset. One has the option for setting the serial number in instrument for various self-calibration functions. A PC can be connected with the device for real-time data monitoring.

Parameters Unit Technical Parameters
Model   SAT-4E11 SAT-4E12 SAT-4E13
Detector   InGaAs
Wavelength nm 850~1700
Working Wavelength nm 850, 980, 1300, 1310, 1490, 1550, 1625
Measurement Range dBm -70~10
Measurement Range W 0.1nW~10mW 10nW~400mW 10nW~1W
Measurement accuracy ±5%
Optical interface FC, ST, SC, MU/LC(optional)
Resolution dBm:0.01dBm W:(0.1~1)%
Power supply 2X1.5V alkaline cells
Operating temperature °C -10~+50
Storage temperature °C -40~+70
Dimension mm L X W X H: 140 X 72 X 38
Weight Kg 0.25

Yes! I am interested

Related Products

  • International Lab Expo' 2013

  • Analytica Anacon India' 2013

  • India Lab Expo' 2013

  • Kolhapur Industrial Expo' 2013

Phoenix Instruments (A unit of SGM lab Solutions (P) Ltd)

BA-15, Mangolpuri Industrial Area,
Phase-2, Delhi-110034 (India)
Phone: +(91)-(11)-48481414

Member IndiaMART.com© Phoenix Instruments (A unit of SGM lab Solutions (P) Ltd). All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Looking for Product Name ?